OIC-EW MARINA REVIEWER / QUIZ COMPETENCE 7 – PART 6

COMPETENCE 7 – Maintenance and Repair of Electronics and Electrical Equipment

Previous Part button         Next Part Button

Results

-

 Congratulations! Share the result.

Try again. There is always a chance. Review the results.

Next

#1. In a series circuit what is the total applied voltage equal to?

c

Next

#2. If the voltage and the current developed in an AC circuit reach their peak values at the same time (with a phase angle difference of zero), what is the power factor considered to be?

Incorrect!

Next

#3. In a logic circuit, how does a NOT gate function?

Incorrect!

Next

#4. In a short-shunt cumulatively compound wound DC motor, how is the shunt field connected?

Incorrect!

Next

#5. In a dual element time-delay cartridge-type fuse, what type of protection is provided for motor applications?

Incorrect!

Next

#6. Impressed current cathodic hull protection systems are commonly used on modern vessels. What are these systems designed to replace or reduce?

Incorrect!

Next

#7. If you hear a loud buzzing noise coming from a magnetic motor controller, what should you do?

Incorrect!

Next

#8. In addition to testing the calibration of a circuit breaker, what additional maintenance should be routinely performed?

Incorrect!

Next

#9. If the field current of a paralleled AC generator is increased above normal, what will be the net result to the VAR’s and power factor?

Incorrect!

Next

#10. In the flow of one cycle of single phase alternating current past any given point in a circuit, how many times will the current peak to a maximum?

Incorrect!

Next

#11. In general, why are nickel-cadmium storage batteries superior to lead-acid batteries?

Incorrect!

Next

#12. In an alternating current circuit, what factor of a circuit will cause the inductive reactance to vary?

Incorrect!

Next

#13. In a basic AC induction motor, by what means are rotor currents induced in the rotor?

Incorrect!

Next

#14. In a shunt-wound DC generator, with what generator component are the shunt field windings connected in parallel with?

Incorrect!

Next

#15. In an impressed current cathodic protection system, concerning the anodes associated with the hull, what statement is true?

Incorrect!

Next

#16. If the field excitation is increased to one of two alternators operating in parallel and decreased on the other, what will be the result on the alternator with the field excitation increased?

Incorrect!

Next

#17. In a rectified DC diesel electric plant, raising the AC generator’s field excitation current will have what effect on the DC propulsion motor?

Incorrect!

Next

#18. In an inductive-resistive circuit, what is the unit of measure for power associated with just the inductive aspects of the load?

Incorrect!

Next

#19. In a three-phase, wye-wye connected transformer, what is the relationship between line current and phase current?

Incorrect!

Next

#20. In a single element cartridge-type fuse, what type of protection is provided for lighting and general power applications?

Incorrect!

Next

#21. In a logic circuit, what statement is true concerning how the NOR and NAND logic gates function?

Incorrect!

Next

#22. In a diesel electric plant, raising the generator’s field excitation current will have what effect on the DC propulsion motor speed?

Incorrect!

Finish

There are 15 questions for the actual examination for Competence 7 for OIC-EW with a passing rate of 70%. This means that you are only allowed to make 4 mistakes.

DISCLAIMER

The questionnaires contained in this “reviewer” are extracted from the post released by MARINA on their official website and other review materials. Please note that Seaman Kowts is not affiliated with, endorsed by, or connected to the official website of MARINA. The information provided on this website is for general informational and educational purposes only and should not be relied upon as official or authoritative. If you require official information or services, please visit the official website or any relevant review center. We do not assume any responsibility or liability for any consequences resulting from the use of information or services provided on this website.

Share this
Verified by MonsterInsights